Product List
FGR200 - Positive Displacement Flow Meter
- High pressure rating
- Applicable to various viscous media
- Flow direction detectable (pulse output model only)
- High repeatability and accuracy
- Pulse / analog output selectable
- Wide measuring range
- Less pressure loss
Applications
- Printing ink measurement
- Resin/glue/silica gel measurement
- Hydraulic oil/lubricating oil/grease measurement
- Cooling liquid measurement
- Solvent measurement
- Fuel oil measurement
- Polyurethane measurement
- Braking fluid measurement
- Cylinder position measurement
Specifications
Applicable medium | Liquids |
Accuracy (at 30cst ) | ±0.5% of reading (turndown ratio of 1:10); ±1% of reading (measuring range) |
Repeatability | ±0.1% of reading |
Pressure rating | 420bar (stainless steel); 100bar (aluminum) |
Temperature | |
Ambient | -40 … 85℃ |
Medium | -40…100℃ (Max. 200℃ for high temperature type) |
Materials | |
Body | 316 stainless steel or aluminum |
Gear | Stainless steel |
Sealing | FPM ( NBR, PTFE optional) |
Bearing | Stainless steel ball bearing or tungsten carbide journal bearing |
GS - Single hall effect pickoff with pulse output amplifier / GH - Single high temperature hall effect pickoff with pulse output amplifier | |
Power supply | 12…30VDC |
Current consumption | 8mA |
Outputs | NPN OC output; NPN OC output+pull-up resistor |
Reverse polarity proof | Yes |
Short-circuit proof | Yes |
Operating temperature | -40…120℃; -40…200℃ (high temperature type) |
Ambient temperature | -40…85℃ |
Electrical connection | M12x1plug; DIN43650-A plug (solenoid plug) |
Protection class | M12X1plug: IP67; DIN43650-A plug: IP65 |
GA - Hall effect pickoff with analog output amplifier / GAH - High temperature hall effect pickoff with analog output amplifier | |
Power supply | 12…30VDC |
Current consumption | Voltage analog output: 7mA; current analog output: <12mA |
Outputs | 0…10V; 3-wire (0) 4…20mA |
Reverse polarity proof | Yes |
Short-circuit proof | Yes |
Operating temperature | -40…120℃; -40…200℃ (high temperature type) |
Ambient temperature | -40…85℃ |
Electrical connection | M12x1plug; DIN43650-A plug (solenoid plug) |
Protection class | M12X1plug: IP67; DIN43650-A plug: IP65 |
DWEG - Smart control unit with hall effect pickoff / DWEGH - Smart control unit with high temperature hall effect pickoff | |
Power supply (Us) | 12 ... 30Vdc |
Current consumption | <20mA |
Switching output | |
Switching type | Push-pull compatible with NPN and PNP |
Current | 500mA @24Vdc |
Current analog output | |
Output type | 3 / 2-wire 4...20mA programable |
Load RA(ohm) | RA≤(Us-10) / 0.02 |
Linearity | ≤±0.5% of reading |
Voltage analog output | |
Output type | 3-wire 0...5V/1...5V programable |
Load RA(ohm) | RA≥5K |
Linearity | ≤±0.5% of reading |
Accuracy | ≤±0.5% of reading |
Temperature | |
Operating temperature | -40…120℃; -40…200℃ (high temperature type) |
Ambient / storage | -40 ... 85℃ |
Display | 8mm height, red 4-digit LED |
Material | |
Display head | 304 stainless steel (316L customized) + PP |
Housing | 304 stainless steel (316L customized) |
Protection class | IP67 |
Electrical connection | M12 x 1 plug |