LC150 - High Temperature Capacitive Level Meter
  • Optional intrinsically safe model
  • High pressure resistant
  • High/low temperature resistant
  • Applicable to various media
  • Quick connecting, no moving parts
  • High temperature resistant(up to300℃)
Applications
  • Level measuring
  • Material level measuring
  • Petrochemical industry
  • Energy industry
  • Water treatment
  • Hydraulic/lubrication system
Specifications
Measuring range (Rod length L) For details see Temperature and Pressure Resistance
Applicable medium

Conductive liquids / non-conductive fluids / powder / bulk-solid materials

Current consumption
    Current output Signal current
    Voltage output About 8mA
Power supply
    Current output 9…36Vdc,9…30Vdc(explosion proof )
    Voltage output 16…36Vdc
Current analog output
    Output 2-wire 4…20mA
    Load RA Rmax=750Ω
Voltage analog output
    Output 3-wire 0...10V
    Load RA Rmin>1KΩ
Sensitivity ranges (PF) 20;30;50;100;150;300;500;1000
Initial capacity regulation ratio Min. 1: 2
Linearity Max. 1%
Temperature error Max. 0.05%/K
Voltage error
    Current output Max. 0.3uA/V
    Voltage output Max. 0.1mV/V
Material
    Housing 304 stainless steel
    Rod For details see 'Model Number'
    Coated FEP
Protection class IP65/IP67
Electrical connection Solenoid plug
Explosion proof parameters
    Grade Ex ia IIB T5
    Power supply 9…30Vdc
    Temperature range -20...60℃ (0 zone)
    Pressure range 0.08 ... 0.11MPa (0 zone)